All issues of organizing autonomous heat supply and hot water preparation are decided by the acquisition of one boiler capable of serving both systems. Not knowing the principle of operation of a double-circuit gas heating boiler, it would be illogical not only to make a purchase, but also to operate the unit. Do you agree?
We will talk about the operation of the heater, consider all its strengths and weaknesses. Understanding the basis of the operation of equipment, you can easily take advantage of all its advantages. And if necessary, it will be possible to identify failures in time, understand and eliminate the causes of their origin.
The device of the boiler for servicing two circuits
A double-circuit gas heat generator differs from a single-circuit analogue in that instead of one heat exchanger, it has two, they are called primary and secondary in technical terminology.
The first, i.e. primary heat exchanger located directly in the flame combustion zone. Its task is to heat the coolant for the functioning of the heating network. The secondary heat exchanger is responsible for the operation of the hot water supply.
Stable operation of the heater is possible with the coordinated operation of all its components. Information on the main functional units will help to understand the principle of operation of the equipment
The design of any dual-circuit unit includes the following standard elements:
- Combustion chamber with a burner block;
- Heat exchangers;
- Control devices and equipment protection.
To understand the features of the device of gas boilers of a double-circuit variety, we dwell on each of its structural elements.
Types of gas burners for double-circuit boilers
The burner of the gas boiler is responsible for obtaining sufficient heat necessary for the functioning of the heating and the hot water supply circuit. Thermal energy is obtained by burning fuel. The burner is placed in a combustion chamber, into which air is pumped in addition to gas. It is needed for the combustion process.
Depending on the operating conditions, the burners can be classified into the following types:
- Single level burner. A unit with a similar burner can operate in only two modes - “Stop” and “Start”. Such boilers, despite the low efficiency and reduced service life, are popular due to the simplicity of design and low cost.
- Two-level burner. A heater with such a burner can operate at full and half power. Its advantages are noticeable in the warm season, when there is no need to operate the device at full power to heat not too cold water.
- Modulating burner. A smart boiler system with a similar burner allows you to configure and adjust the power. Such a boiler is characterized by a high service life and efficiency, but at the same time it is an order of magnitude higher than units with single-level and two-level burners.
Burners are divided into designs of open and closed type. When the burner is open, the air necessary for burning fuel comes directly from the room in which the boiler is located. For the removal of combustion products, a chimney is required, which should provide sufficient natural draft.
Atmospheric heating units are equipped, as a rule, with an ordinary metal pipe, turbine ones with a coaxial chimney.Depending on the technical conditions of the room, the smoke channel is placed vertically or built at an angle. Corner options are led out through the wall to the street or connected to a public chimney shaft.
A gas burner is the main element of a double-circuit gas boiler, it is responsible for burning fuel and generating thermal energy in the required amount
Turbocharged boilers are equipped with closed combustion chambers, into which air cannot flow spontaneously. They are safer and more reliable in operation, but more expensive and more difficult to operate. In addition to the chimney, boilers with closed burners need a channel through which the oxygen required for combustion is supplied to the chamber.
That’s why they equip turbine boilers with coaxial pipes, because in addition to exhausting smoke, they also draw in fresh air from the street. It happens that for normal operation two coaxial flues are connected to a closed combustion chamber. In addition, the entire structure is supplemented by an air supply pipe.
All such boiler models are equipped with fans that provide smoke movement, multi-level protection systems, automation. For the operation of the listed devices and systems, electricity is needed. Their minus is energy volatility, which increases operating costs.
Varieties of heat exchangers for gas units
If a fuel is burned with the aid of a burner in order to obtain heat, the heat exchanger provides this heat for further transfer to water. As already mentioned, the primary and secondary heat exchangers are present in the dual-circuit design.
The primary heat exchanger is located directly above the burner and is a finned tube curved in the form of a snake. Under the influence of a flame, the water in the heat exchanger heats up and moves through a three-way valve further into the wiring of the heating system.
The secondary heat exchanger is a system of corrugated plates that are assembled in a single unit with two pairs of holes. Each pair of holes has its own functions.
Water flows from the water supply pipe through one of the pairs, and the coolant moving into the heating circuit moves through the second. A similar system of plate and tubular heat exchangers is called dual.
The primary and secondary heat exchanger are combined in one system, the correct operation of which is ensured by a special three-way valve
There are heating devices in which instead of a dual system, a bithermic heat exchanger of a complex configuration is used. Such a heat exchanger is made of copper, it is a pair of tubes located one in the other. The coolant moves through the outer tube, and water through the inner tube to ensure the operation of the hot water supply.
The bithermic heat exchanger of the heat carrier and water heater has a complex configuration when the tube of one circuit is placed in the tube of another circuit
Boilers with a bithermic heat exchanger are more difficult to operate, since both heat exchangers are represented by a single unit, which makes it difficult to clean it from scale. But such heating devices are in demand, as they differ in small overall dimensions and high speed of heating water.
Automation or boiler control unit
The boiler automation is responsible for safe and stable operation. It monitors the temperature of the water in the components of the hot water supply, maintains the temperature of the coolant in the heat supply lines. The automation of the gas boiler does not allow the operation of the heater in case of dangerous situations.
The unit interrupts work or does not turn on in such cases:
- Reduced pressure in the gas system;
- Lack of traction;
- Absence or critical coolant overheating.
The control unit that controls the operation of protection and process automation devices is represented by a set of switches, microcircuits, or a combination thereof. In addition to ensuring safety and temperature control, he monitors the operation of the circulation pump and fan.
Modern gas boilers are distinguished by the presence of intelligent control, in the software of which there are various operating modes.
Principle of work and specifics
Many owners of gas equipment do not even think about how a double-circuit gas boiler actually works. They mistakenly believe that heating of water and the heating circuit occurs simultaneously. In fact, everything does not look so rosy.
A double-circuit gas boiler cannot simultaneously operate in two modes, ensuring the operation of heating and domestic hot water systems. This is confirmed by the presence in his device of a three-way valve
In normal mode, the boiler constantly works only to heat the coolant circulating in the system. In this case, the switching frequency and the intensity of the flame are controlled by a temperature sensor. At the same time as the burner, the circulation pump is started if the action of the heating system is not based on the natural circulation of the coolant.
The space at the bottom of the wall-mounted boiler is designed for gas supply, cold water connection, as well as the taps of the domestic hot water system and the heating circuit
In fact, when the temperature of the coolant reaches a predetermined value, the sensor sends a signal indicating a decrease in burner activity. Until the temperature drops to the set value, the boiler will be in passive mode. Then again the command from the sensor to the automation to activate the fuel supply valve.
Double-circuit boiler operation scheme
The presence of a hot water supply system slightly complicates the operation of a double-circuit gas boiler. The heat carrier heated by the burner, moving along the heat exchanger, provides heating for the plate heat exchanger along which water from the water supply system moves.
A structural diagram of a double-circuit gas boiler with both a bithermic and two conventional heat exchangers. In the first version, there is no need to use two heat exchangers
The simultaneous use of the dual-circuit model in heating and hot water mode is not possible. When the hot water tap is activated, due to the three-way thermostatic valve, the circulation of the coolant along the heating mains stops. The boiler enters the mode of moving water along the circuit with a plate heat exchanger, which is used to heat water for domestic purposes.
With a significant consumption of hot water for a long time, the operation of the boiler with a focus on heating can be paralyzed. There are two ways to solve the problem - to provide for the installation of a more powerful heating device or to include an indirect heating boiler in the arrangement.
With the active use of the DHW system, it is possible to install a dual-circuit boiler with a built-in boiler. In this case, fuel consumption is slightly increased due to the fact that in the pause between the cycles of the heating system, the burner energy is used to maintain the water temperature in the additional gas water heater.
A certain supply of hot water in the built-in boiler allows you to use the DHW system without disconnecting the heating circuit. As a result, both systems operate alternately, with no overheating of the liquid and extending the life of the heat exchanger.
A boiler with a built-in standard boiler not only provides a sufficient spare volume of hot water, but also helps to avoid a long shutdown of the heating circuit
The built-in standard boiler allows you to get hot water at the right temperature at any time, the supply of which is provided in automatic mode. While a DHW flow system takes several minutes to heat water to the desired temperature.
Types of execution of gas boilers for two circuits
Features of the gas equipment is largely determined by the embodiment of the heater. Modern boilers are available in two form factors - floor and wall.
When choosing a design option, you need to focus on the size of the heated area, the activity of using the DHW system. You need to understand that wall-mounted boilers are more compact, but at the same time they have much less power.
The double-circuit wall-mounted gas boiler is compact in size and modern in design, but is effective only for heating small areas with moderate consumption of hot water
The choice of a wall-mounted double-circuit boiler can be justified if the heated area does not exceed 200 square meters, and the total capacity of the domestic hot water system is not more than 14 l / min.
The small dimensions of the wall-mounted boiler, although it seems a virtue, in fact hide a lot of minuses. Compactness is achieved through the use of thinner heat exchanger tubes. Besides the fact that they have a shorter service life, there is a possibility of their clogging.
In floor installations, more massive and reliable cast-iron heat exchangers are used. This not only increases the degree of reliability of the heater, but also extends its service life.
Advantages and disadvantages of dual-circuit devices
The advantages of a dual-circuit heating unit are as follows:
- Economical fuel consumption. The direction for comparison is the use of a dual-circuit boiler or a single-circuit boiler with indirect heating.
- Compact size. The overwhelming majority of double-circuit boilers are represented by wall-mounted heating devices. They are easy to place both in the utility rooms and in the small-sized kitchen.
- Universality. There is no need to buy additional equipment and solve issues with its compatibility with the boiler.
In one unit, a flowing water heater, a heating device and a circulation pump are already successfully combined into a single automated system.
Obviously, along with advantages, there are also disadvantages:
- The impossibility of the simultaneous action of heating and the DHW circuit. In this regard, a significant consumption of hot water can cause a decrease in temperature in the house.
- Power limitations of wall models. Compact wall-mounted boilers, due to the minimum size of the burner, are not able to provide the required temperature conditions at maximum pressure. A similar drawback is observed with the remote placement of water intake points.
- Sensitivity to water quality. The secondary plate heat exchanger is demanding on the quality of the consumed water. The presence of impurities becomes the reason for the use of means to reduce its rigidity, and to conduct cleaning of the coolant.
Another criterion for evaluating a dual-circuit boiler is its cost. The price of a dual-circuit heater is higher than the price of a single-circuit analog.
However, if we consider the availability of a hot water supply system and ways to resolve the issue in the case of installing a single-circuit boiler, then when the indirect heating boiler is included in the assembly circuit, the price of the double-circuit will be lower.
The following video will familiarize with the structural components and the principle of operation of gas heating equipment:
A detailed acquaintance with the features and principle of operation of dual-circuit gas units makes it possible to determine the advantages of their operation.The purchase of such heaters will help to save on the purchase of additional equipment necessary for the organization of a hot water supply system.
If one of the circuits breaks down, the operation of another is possible, and replacing the circuit will always be cheaper than repairing a separate heating installation. A double-circuit boiler can also be used in the warm season, operating it only in the mode of heating water for domestic needs, which is the convenience and efficiency compared to the purchase of individual units.
Tell us about how to choose a dual-circuit gas boiler for arranging your own house / apartment / cottage. What has become the decisive criterion for you in your choice? Please share useful information on the topic, photos in the block below, ask questions.